| MODEL |
AIM2012 |
| Capacity |
18,000/H Max |
| Adaptable Containers |
Ampule, Vial, Syringe etc. |
 |
Body Diameter |
10-19 20-30 (Two-step, 9,000/H) |
Total Height |
45-120mm |
| Detection System |
Light transmission SD system for Particles, CCD cameras for Cosmetic defects, Oscillate Drive Camera Table, Oscillate Drive SD Table, Starwheel |
| Power Supply |
3 200V-480V (adjustable) 4kVA |
Compressed Air |
Over 0.4MPa ab. 200-400NL/Min |
| Weight |
ab. 3,500kg |
|
| MODEL |
AIM2022 |
| Capacity |
24,000/H Max |
| Adaptable Containers |
Ampule, Vial, Syringe etc. |
 |
Body Diameter |
10-19 20-30 (Two-step, 12,000/H) |
Total Height |
45-120mm |
| Detection System |
Light transmission SD system for Particles, CCD cameras for Cosmetic defects, Oscillate Drive Camera Table, Oscillate Drive SD Table, Starwheel |
| Power Supply |
3 200V-480V (adjustable) 4kVA |
Compressed Air |
Over 0.4MPa ab. 200-400NL/Min |
| Weight |
ab. 4,000kg |
|
| MODEL |
AIM5012 |
| Capacity |
12,000/H Max |
| Adaptable Containers |
Ampule, Vial, Syringe etc. |
 |
Body Diameter |
10-29 30-45 (Two-step, 6,000/H) |
Total Height |
45-120mm |
| Detection System |
Light transmission SD system for Particles, CCD cameras for Cosmetic defects, Oscillate Drive Camera Table, Oscillate Drive SD Table, Starwheel |
| Power Supply |
3 200V-480V (adjustable) 4kVA |
Compressed Air |
Over 0.4MPa ab. 200-400NL/Min |
| Weight |
ab. 3,500kg |
|
| MODEL |
AIM5022 |
| Capacity |
18,000/H Max |
| Adaptable Containers |
Ampule, Vial, Syringe etc. |
 |
Body Diameter |
10-29 30-45 (Two-step, 8,000/H) |
Total Height |
45-120mm |
| Detection System |
Light transmission SD system for Particles, CCD cameras for Cosmetic defects, Oscillate Drive Camera Table, Oscillate Drive SD Table, Starwheel |
| Power Supply |
3 200V-480V (adjustable) 4kVA |
Compressed Air |
Over 0.4MPa ab. 200-400NL/Min |
| Weight |
ab. 4,000kg |
|
| MODEL |
AIM7012 |
| Capacity |
6,000/H Max |
| Adaptable Containers |
Ampule, Vial, Syringe etc. |
 |
Body Diameter |
10-45 |
Total Height |
45-120mm |
| Detection System |
Light transmission SD system for Particles, CCD cameras for Cosmetic defects, Oscillate Drive Camera Table, Oscillate Drive SD Table, Starwheel |
| Power Supply |
3 200V-480V (adjustable) 4kVA |
Compressed Air |
Over 0.4MPa ab. 200-400NL/Min |
| Weight |
ab. 3,500kg |
|
| MODEL |
AIM7022 |
| Capacity |
8,000/H Max |
| Adaptable Containers |
Ampule, Vial, Syringe etc. |
 |
Body Diameter |
10-45 |
Total Height |
45-120mm |
| Detection System |
Light transmission SD system for Particles, CCD cameras for Cosmetic defects, Oscillate Drive Camera Table, Oscillate Drive SD Table, Starwheel |
| Power Supply |
3 200V-480V (adjustable) 4kVA |
Compressed Air |
Over 0.4MPa ab. 200-400NL/Min |
| Weight |
ab. 4,000kg |
|
|